Patient Monitor PM12/PM8

●HD display

Wide Viewing angle

●7200 Memory

●Multi-touch operation

●Smart, Light, Easy operation

\ Product Contents

Parameters: ECG, RESP, Temp, SPO2, PR, NIBP

●Full touch screen, easy to operate and easy to clean

●Colorful and clear 12.1" or 8" TFT screen

●Support AC, USB Type-C and DC power supply

●Built in rechargeable large capacity lithium battery, convenient for patients transferring

●IP22 waterproof

●Support desktop, bracket and other installation methods.

●Automatic accousto-optic double alarm

●Anti defibrillation and high frequency electric knife interference.

●Support multi-ple languages

\ Product Illustration
\ Product Specification


S/N
Feature
Description
1
Product name
12 inch touch screen multi parameter hospital patient monitor
2
Model
PM12
3
Display
Full touch screen , easy to operate and easy to clean
Colorful and clear 12.1"or 8"TFT screen
4
Power
AC, USB Type-C, DC power, rechargeable large capacity lithium battery
5
Convenience
Support desktop, bracket and other installation methods
6
Alarming
Automatic acousto-optic double alarm
3 level audible and visual alarming
Dual alarm light for physiological and technical alarming
7
Hightlight
Anti defibrillation and high frequency electric knife interference
8
Data& Storage
7200 groups measurements
9
Language
Multi such as English, Spanish, French, German or others
10
Waterproof
IP22
11
Usage
Adults, children and neonates. uitable for bedside, ICU, OR
\ User Instructions

ECG:

Lead: 3 leads or 5 leads, I,Ⅱ,Ⅲ,aVR,aVL,aVF,V
Heart Rate: 15﹣300 bpm
Accuracy: ±1% or ±2bpm
(whichever is greater)
Resolution: 1 bpm
Sample rate: 250sps
Sign width: 70 to 120ms(Q to S)



Temperature:

Range: 5℃-50.0℃(41.0℉-122.0℉)
Unit: ℃ or℉
Resolution: 0.1℃ or℉
Machine accuracy: ±0.1℃
Temp cable accuracy: ±0.1℃


NIBP:

SYS: 30-250 mmHg
DIA: 10-210 mmHg
Mean: 20-230 mmHg
Static pressure accuracy: ±3mmHg
Clinical accuracy: Max average deviation±5mmHg;Max Standard deviation±8mmHg

Respiration:

Range: 0-120 breaths per minute
Respiration Resolution: 1 breath per minute
Accuracy: ±3 breath per minute
Detection sensitivity: 0.5Ω at 500ΩInput source impedance
Pacer detection
Amplitudes of pacemaker pulses: ±2 to ±700mV
Width: 0.25 to 2 ms


SPO2:

Range: Saturation of blood oxygen:30%-100%
PR: 30-250 bpm
Resolution: Saturation of blood oxygen:1%
PR: 1bpm
Accuracy: Saturation of blood oxygen:within 70%~100%, ±3%
PR: ±3bpm

Back

Previous:Is already the first one

Next:Is already the last one